Section One BBS

Welcome, Guest.


Subject: failed password Date: Tue Mar 25 2025 02:02 pm
From: Digital Man To: Greg Meckel

  Re: failed password
  By: Greg Meckel to Digital Man on Tue Mar 25 2025 07:19 am

 >  > Do you multiple linked-addresses for this same linked-node (e.g. in
 >  > sbbsecho.ini / echocfg)? If so, are they all using the same password?
 >
 >  > BinkP has some funky stuff with passwords and identities when multiple
 >  > addresses (AKAs) are used and it's possible that when you receive an
 >  > inbound BinkP connection, a different password is being expected/used
 >  > than when you make an outbound connection to the same linked-node. Double
 >  > check your configuration.
 >
 > I only have 1 linked node and only 1 linked address. Passwords are the same
 > in sbbsecho.ini and echocfg.

And you only have one address in SCFG->Networks->FidoNet->System Addresses?

Another possibility is a mismatch between 3D and 4D/5D addresses (e.g. 1:2/3 and
 1:2/3@fidonet are not the same address in all scenarios).
-- 
                                            digital man (rob)

Steven Wright quote #6:
A conscience is what hurts when all your other parts feel so good.
Norco, CA WX: 79.6°F, 39.0% humidity, 11 mph W wind, 0.00 inches rain/24hrs
---