Subject: SVDM - outbound calling issue Date: Fri Dec 23 2022 04:04 pm
From: Deon George To: GitLab note in main/sbbs

https://gitlab.synchro.net/main/sbbs/-/issues/468#note_2961

OK, I'll get your debug file after I've submitted this.To answer your questions,
no, dont use -r (or Rate) in the SVDM.INI file. And -d is only used since I
started debugging this. (Not sure where the `debug log` is, but it outputs to
the screen on exit: `rx_delay: 0`.)I start SVDM with "-raw -d -l -p2021 pop %1
%2 %3 %4" (but generally only start the bat file with 1 argument)Attached, I've
created more debugging with dbgview - "a good session" and a "bad session",
together with tcpdump on the linux side. (The times in the timestamps are in
sync.)I'm guessing (and my memory of how this starts), on it, the mailer sends
0d 0a to start the EMSI session (the two bytes), where the server responds with
two EMSI_REQ, the client should respond with an EMSI_DAT.In the good logs, you
can see this starting.In the bad logs, I'm thinking that SVDM doesnt receive (or
pass through) the EMSI_REQs as received, so the mailer is still sending the 0d
0a to start the session...[W7-SVDM-DEON.zip](/uploads/78432bfe07a1c8e4212a5f5222
829848/W7-SVDM-DEON.zip)
--- SBBSecho 3.20-Linux
 * Origin: Vertrauen - [vert/cvs/bbs].synchro.net (1:103/705)